A11-V1.0 Ultrasonic Distance Sensor with Bracket, 21 to 300 cm

A11-V1.0

Ultrasonic Distance Sensor with Bracket, 21 to 300 cm

Ultrasonic distance sensor with UART, PWM and switch outputs, measuring 21-300 cm in one variant and 23-200 cm in another, with temperature compensation and a mounting bracket.

Range
21-300cm
Output
UART/PMW/switch output
Blind zone
21cm
Supply voltage
DC3.3-5V

Features

  • Blind zone 21cm or 23cm by variant
  • Accuracy ±1cm + 0.3% of distance
  • Static current 15uA
  • DC3.3-5V supply
  • HY2.0-4Y terminal wire, 30 cm

Full specifications

PDF A11-V1.0 Datasheet EN
A11-V1.0 specifications as published. Values are typical unless stated.
Planar mode
Operating voltageDC3.3-5V
Static current15uA
Measuring range21-300cm
Blind zone21cm
OutputUART/PMW/switch output
Accuracy±1cm+detection distance*0.3%
Temperature compensationYes (temperature compensated)
Human-body mode
Measuring range23-200cm
Blind zone23cm
Wiring
Wire length30 cm
ConnectorHY2.0-4Y terminal wire
Pin definition
Pin 1 (red)VCC
Pin 2 (black)GND
Pin 3 (yellow)RX
Pin 4 (white)TX
Dimensions
Probe side view29±0.2 mm
Probe side view16.5±0.2 mm
Probe side view14±0.2 mm
Probe side view8.6±0.2 mm
Cable length300±20 mm
Probe side view5.7 mm
Probe top view23.8±0.2 mm
Probe top view16.4±0.2 mm
Probe top view8.6 mm
Bracket side view27.7±0.2 mm
Bracket side view24.5±0.2 mm
Bracket side view25.2±0.2 mm
Bracket width30±0.2 mm
Bracket length80±0.2 mm
Bracket front hole diameter18.8±0.1 mm
Operating voltage3.3-5 V
OutputUART / PWM / switch output
Measuring range20-300 cm

Dimensions and wiring

Drawing 1 for A11-V1.0

Questions about the A11-V1.0

What is the range of the A11-V1.0?

The A11-V1.0 ultrasonic distance sensor with bracket, 21 to 300 cm is specified with a range of 21-300cm.

What is the output of the A11-V1.0?

The A11-V1.0 ultrasonic distance sensor with bracket, 21 to 300 cm is specified with a output of UART/PMW/switch output.

What is the blind zone of the A11-V1.0?

The A11-V1.0 ultrasonic distance sensor with bracket, 21 to 300 cm is specified with a blind zone of 21cm.

Where can I get the A11-V1.0 datasheet?

The A11-V1.0 datasheet is a free PDF on this page, with the full specification table. For drawings in CAD format or a custom version, contact DWIN sales.

Ask about the A11-V1.0

Send your application, quantity and interface. We reply with pricing, lead time and sample availability.

Request a quote