L02-V1.0
Low-Power External Ultrasonic Liquid Level Sensor, UART
Under-container ultrasonic liquid-level sensor with UART auto output, 20-2000 mm range, 1 uA standby current and 2.8-5 V supply for battery-powered use.
- Range
- 2-200 cm
- Accuracy
- ±(5+S*0.5%) mm
- Output
- UART auto serial
- Blind zone
- Self-adaptive mm
Features
- Non-contact measurement through the container wall
- Upper and lower limit alarm
- Self-adaptive blind zone
- Repeatability error ±1 mm
- Measuring angle 3–12 °
Typical applications
Full specifications
PDF L02-V1.0 Datasheet| Operating temperature | -15 to +60 °C |
|---|---|
| Storage temperature | -25 to +80 °C |
| Resolution | 1 mm |
| Model (as printed) | L023MUW-V1.0 |
| Operating voltage | 2.8–5 V |
| Standby current | 1 uA |
| Average current | 2.5–5 mA |
| Blind zone | Self-adaptive mm |
| Detectable liquid height | 20–2000 mm |
| Working cycle | 1 S |
| Output | UART auto serial |
| Response time | 1 S |
| Repeatability error | ±1 mm |
| Accuracy at normal temperature | ±(5+S*0.5%) mm |
| Measuring angle | 3–12 ° |
| Dimensions | |
| Body dimension (side view) | 27.7±0.5 mm |
| Body dimension (side view) | 17±1 mm |
| Cable length | 300±10 mm |
| Operating voltage | 2.8-5 V |
| Output | UART auto output |
| Measuring range | 2-200 cm |
Dimensions and wiring
Questions about the L02-V1.0
What is the range of the L02-V1.0?
The L02-V1.0 low-power external ultrasonic liquid level sensor, uart is specified with a range of 2-200 cm.
What is the accuracy of the L02-V1.0?
The L02-V1.0 low-power external ultrasonic liquid level sensor, uart is specified with a accuracy of ±(5+S*0.5%) mm.
What is the output of the L02-V1.0?
The L02-V1.0 low-power external ultrasonic liquid level sensor, uart is specified with a output of UART auto serial.
Where can I get the L02-V1.0 datasheet?
The L02-V1.0 datasheet is a free PDF on this page, with the full specification table. For drawings in CAD format or a custom version, contact DWIN sales.