Level and temperature transmitter for 0~3.5m H2O to 0~350m H2O and -40~60°C, with a silicon oil pressure sensor, platinum temperature sensor and 4~20mA output.

Range
0–3.5mH2O to 0–350mH2O
Output
4–20mA
Protection
IP68
Supply voltage
10VDC~30VDC

Features

  • Silicon oil pressure sensor
  • Platinum temperature sensor
  • Accuracy 0.5%BFSL or 1.0%BFSL
  • Cable outlet electrical connection
  • 10VDC~30VDC supply

Typical applications

  • River and lake monitoring
  • Deep well and groundwater monitoring
  • Storage vessel level and temperature
  • Sewage and storm-water basin monitoring

Full specifications

PDF CS-WPT400 Datasheet EN
CS-WPT400 specifications as published. Values are typical unless stated.
Performance parameters
Reference conditionsTemperature: 25°C, Power: 12VDC, RH: 45%~75%, Atmospheric pressure: 86KPa~106KPa
Pressure range0–3.5mH2O to 0–350mH2O
Temperature range-40–60°C, but can’t beyond the temperature of seal material(Note1)
Pressure output4–20mA
Power supply (u+)10VDC~30VDC
Output load≤(U+ -10) / 0.023Ω(MAX:600Ω)
Over voltage30VDC
Reverse voltage-30VDC
Pressure accuracy at room temperature±0.5%F.S standard, ±1%F.S optional (include no-linearity, hysteresis, repeatability, and calibration error)
Storage temperature-40–100°C
Long-term stability±0.5%F.S / year
Settling time(10%~90%) ≤10ms
Overload pressure≥ 150%F.S
Burst pressure≥ 200%F.S
Pressure connectionStandard connector
Temperature output4–20mA
Electrical connectionCable outlet
Insulation resistance≥ 100MΩ@50VDC
Vibration resistance10g, 5–2000Hz
Shock resistance20g, 11ms half sine
Ingress protectionIP68
Sealings materials for wetted partNBR O-Ring default, FKM optional
Housing material304 stainless steel default, 316L stainless steel and Titanium optional
Cable materialPE default, PUR and FEP optional
Note 1Operating temperature shall not go beyond the temperature range of the seal materials. Default NBR suits medium temperature -20–100°C; with an FKM seal ring the medium temperature should be between -15–125°C.

Dimensions and wiring

Drawing 1 for CS-WPT400

Questions about the CS-WPT400

What is the range of the CS-WPT400?

The CS-WPT400 level and temperature transmitter, platinum sensor is specified with a range of 0–3.5mH2O to 0–350mH2O.

What is the output of the CS-WPT400?

The CS-WPT400 level and temperature transmitter, platinum sensor is specified with a output of 4–20mA.

What is the protection of the CS-WPT400?

The CS-WPT400 level and temperature transmitter, platinum sensor is specified with a protection of IP68.

Where can I get the CS-WPT400 datasheet?

The CS-WPT400 datasheet is a free PDF on this page, with the full specification table. For drawings in CAD format or a custom version, contact DWIN sales.

Ask about the CS-WPT400

Send your application, quantity and interface. We reply with pricing, lead time and sample availability.

Request a quote