CS-LAS
Single-Axis Accelerometer, 0.5–4.5V Analog Output
Single-axis accelerometer with 0.5–4.5V analog output, ± 1g range (selectable up to ± 100g), 1000 ± 30 mV / g sensitivity and 4000 g impact resistance.
- Output
- 0.5–4.5 V
- Supply voltage
- 5 ± 0.25 VDC
Features
- Small size, light weight
- Good shock and vibration performance
- Bandwidth ≥50 Hz, selectable ≤ 400Hz
- 5 ± 0.25 VDC supply
- Size 19.5 × 18.8 × 8.4 mm
Typical applications
Full specifications
PDF CS-LAS Datasheet| Electrical | |
|---|---|
| Supply voltage | 5 ± 0.25 VDC |
| Supply current | ≤ 2 mA |
| Output | 0.5–4.5 V |
| Performance | |
| Axial | X |
| Range | ± 1g (range selectable ± 1 ~ ± 100g) |
| Bandwidth | ≥50 Hz (selectable bandwidth of ≤ 400Hz) |
| Sensitivity | 1000 ± 30 mV / g |
| Resolution | ≤ 0.001g |
| Nonlinear | ≤ 0.5% Fs |
| Bias (25 °C) | 2.5 ± 0.1V |
| Start time | ≤ 1 s |
| Environmental | |
| Operating temperature | -40 °C ~ + 70 °C |
| Storage temperature | -40 °C ~ + 125 °C |
| Impact resistance (0.5ms) | 4000 g |
| Physical | |
| Weight | 40 g |
| Size | 19.5 × 18.8 × 8.4 mm |
Questions about the CS-LAS
What is the output of the CS-LAS?
The CS-LAS single-axis accelerometer, 0.5–4.5v analog output is specified with a output of 0.5–4.5 V.
What is the supply voltage of the CS-LAS?
The CS-LAS single-axis accelerometer, 0.5–4.5v analog output is specified with a supply voltage of 5 ± 0.25 VDC.
Where can I get the CS-LAS datasheet?
The CS-LAS datasheet is a free PDF on this page, with the full specification table. For drawings in CAD format or a custom version, contact DWIN sales.